Australian Energy Regulator
 
 
 
Contact us
About us
News & speeches
Publications
Careers
Glossary
 

Weekly report 5–11 November

Issue date

17th November 2006

(The full report is available in PDF form below)

Overview

Spot prices for the week averaged between $22/MWh in Queensland and $38/MWh in Tasmania and South Australia.

Turnover in the energy market was $105 million.  The total cost of ancillary services for the week was $343 000, or 0.3 per cent of energy market turnover.

Significant variations between actual prices and those forecast 4 and 12 hours ahead occurred in 46, or 15 per cent of all trading intervals.  Demand forecasts produced 4 and 12 hours ahead varied from actual by more than 5 per cent in 15 per cent of all trading intervals across the market.  These variations were most frequent in Tasmania, occurring in 40 per cent of all trading intervals.

The AER welcomes comments on the information contained in, or the layout of, the report. Comments should be sent to Peter Adams or Mark Wilson, AER, GPO Box 922, Adelaide SA 5000 (email AERInquiry@aer.gov.au; fax (08) 8213 3414).

Price summary

Energy prices

Figure 1 sets out national demand and spot prices in each region for each trading interval. Figure 2 compares the volume weighted average price with the averages for the previous week and the same quarter last year. Figure 3 compares the weekly price volatility index on the same basis.

Figure 1  National demand and spot price all regions

Figure 1  Half–hour national demand and prices–5 November 2006

Figure 2  Volume weighted average spot price for energy market ($/MWh)

QLD
NSW
VIC
SA
TAS
Last week
22
28
29
38
38
Previous week
21
25
28
30
36
Same quarter last year
39
73
32
47
63
Financial year to date
24
35
36
40
40
% change from previous week
▲9%
▲13%
▲5%
▲27%
▲5%
% change from same quarter last year
▼43%
▼61%
▼9%
▼18%
▼39%
% change from previous year
▲5%
▼20%
▲18%
▲18%
▼57%

Figure 3  Volatility index* during peak periods

QLD
NSW
VIC
SA
TAS
Last week
0.5
0.71
0.61
0.5
0.19
Previous week
0.33
0.44
0.52
0.48
0.1
Same quarter last year
1.12
1.03
0.83
0.76
0.61

*A definition of the price volatility index is available on the AER website.
http://www.aer.gov.au/content/index.phtml/tag/MarketSnapshotLongTermAnalysis

Price events

The maximum spot prices for the week ranged from $66/MWh in Queensland to $88/MWh in Tasmania.  In South Australia the spot price reached $1687/MWh on Saturday evening, when a combination of lightning near the Heywood interconnector and reduced generation capacity saw the price spike to $10 000/MWh for one five-minute dispatch interval.

There was no low reserve conditions forecast.

FCAS

The total cost of ancillary services on the mainland for the week was $254 000 or 0.3 per cent of the energy market.  Locally sourced lower services were required in Queensland on Wednesday following the reclassification of a non credible contingency event caused by storm activity, affecting QNI.  The cost for locally sourced ancillary services was around $22 000 during this event.

Figure 4 summarises the volume weighted average prices and costs for the eight frequency control ancillary services across the interconnected regions.

Figure 4  Volume weighted average frequency control ancillary service prices (excluding Tasmania)

Raise
Lower
 
6
sec
60
sec
5
min
Reg
6
sec
60
sec
5
min
Reg
Last week($/MW)
0.88
0.16
1.54
3.24
2.29
0.41
0.93
1.05
Previous week ($/MW)
0.63
0.12
0.64
2.41
0.22
0.2
0.52
1
Last quarter ($/MW)
1.76
0.73
1.15
1.54
0.39
2.28
5
1.93
Market cost($1000s)
39
6
89
67
8
6
27
13
% of energy market
0.04%
0.01%
0.09%
0.07%
0.01%
0.01%
0.03%
0.01%

The total cost of ancillary services in Tasmania for the week was $89 000 or 1 per cent of the total turnover in the energy market in Tasmania.

Figure 5 summarises the volume weighted average prices and costs for the eight frequency control ancillary services across Tasmania.

Figure 5  Tasmanian volume weighted average frequency control ancillary service prices

Raise
Lower
 
6
sec
60
sec
5
min
Reg
6
sec
60
sec
5
min
Reg
Last week($/MW)
3.45
0.76
2.47
3.8
0.06
0.08
0.4
0.94
Previous week ($/MW)
1.15
0.81
2.15
3.85
0.1
0.07
0.4
0.98
Last quarter ($/MWh)
4.97
0.49
2.93
3
12.67
0.43
0.82
0.45
Tasmania Market cost($1000s)
18
11
32
20
0
0
0
8
% Tasmania of energy market
0.24%
0.15%
0.42%
0.26%
0.01%
0.01%
0.01%
0.1%

Figure 6 shows the daily breakdown of price for each frequency control ancillary service. It also includes the cost of services sourced locally and in Tasmania.

Figure 6  Daily frequency control ancillary service prices

Figure 6  Daily frequency control service costs–5 November 2006

Figure 7 shows the weekly participation in each of the ancillary service markets on a regional basis.

Figure 7  Regional participation in ancillary services

Figure 7  Regional participation in global frequency control services–5 November 2006

Figures 8 and 9 show 30-minute prices for each of the ancillary services.

Figure 8  Prices for raise services

Figure 8  Half–hour global prices for raise frequency control services–5 November 2006

Figure 9  Prices for lower services

Figure 9  Half–hour global prices for lower frequency control services–5 November 2006

Figures 10 and 11 show the 30-minute Tasmanian price for each of the ancillary services.

Figure 10  Tasmanian prices for raise services

Figure 10  Half–hour Tasmanian prices for raise frequency control services–5 November 2006

Figure 11  Tasmanian prices for lower services

Figure 11  Half–hour Tasmanian prices for lower frequency control services–5 November 2006

Figures 12 and 13 present both the raise and lower requirements for each service over the week.

Figure 12  Raise requirements

Figure 12  5–minute global requirement for raise frequency control services–5 November 2006

Figure 13  Lower requirements

Figure 13  5–minute global requirement for lower frequency control services–5 November 2006

Figures 14 and 15 present both the raise and lower Tasmanian requirements for each service over the week.

Figure 14  Tasmanian raise requirements

Figure 14  5–minute Tasmanian requirement for raise frequency control services–5 November 2006

Figure 15  Tasmanian lower requirements

Figure 15  5–minute Tasmanian requirement for lower frequency control services–5 November 2006

Top

Full report

Market analysis 20061105–20061111.pdf (1.1 MB)
Printer friendly
Market reports
Notify me...
  • Email me if updated